Mass spectrometry terms
From Murray Mass Spectrometry Group
Current list of mass spectrometry terms
Below is the current list of mass spectrometry terms.
Contents |
A
- accelerating voltage
- Redirects to ion source
- accelerator mass spectrometry
- Main page
- accurate mass
- Section of Mass (mass spectrometry)
- adiabatic ionization
- Main page
- adduct ion
- Main page
- alpha cleavage
- Main page
- a-ion
- Redirects to Peptide sequence tag
- ambient ionization
- Main page
- analog ion
- anionized molecule
- appearance energy
- Main page
- appearance potential
- Redirects to appearance energy
- array detector
- associative ionization
- Main page
- associative ion/molecule reaction
- atmospheric pressure ionization
- atomic mass unit
- Main page
- atmospheric pressure chemical ionization
- Main page
- atmospheric pressure matrix-assisted laser desorption/ionization
- Section of matrix-assisted laser desorption/ionization
- atmospheric pressure photoionization
- Section of Ion source
- autodetachment
- Redirects to wikipedia:autoionization
- autoionization
- Main
- average mass
- Section of Mass (mass spectrometry)
B
- base peak
- base peak chromatogram
- bath gas
- β-cleavage
- b-ion
- Redirects to Peptide sequence tag
- blackbody infrared radiative dissociation
- Main page
- buffer gas
C
- cationized molecule
- centroid acquisition
- charge exchange ionization
- charge-exchange reaction
- charge inversion mass spectrum
- charge inversion reaction
- charge-mediated fragmentation
- charge number
- Main page
- charge permutation reaction
- charge remote fragmentation
- Main page
- charge stripping
- charge transfer reaction
- chemical ionization
- Main page
- chemi-ionization
- Main page
- c-ion
- Redirects to Peptide sequence tag
- cluster ion
- collisional activation
- Redirects to collision induced dissociation
- collisionally activated dissociation
- Redirects to collision induced dissociation
- collisional excitation
- Main page
- collision cell
- Redirects to Triple quadrupole mass spectrometer
- collision gas
- collision-induced dissociation
- collision quadrupole
- Redirects to Triple quadrupole mass spectrometer
- collision reaction cell
- Main page
- consecutive reaction monitoring
- constant neutral loss spectrum
- constant neutral mass gain scan
- constant neutral mass gain spectrum
- continuous dynode particle multiplier
- continuous-flow fast atom bombardment
- Redirects to fast atom bombardment
- conversion dynode
- cyclotron motion
- Redirects to Ion cyclotron resonance
D
- dalton
- Disambiguates to wikipedia:atomic mass unit
- Daly detector
- Main page
- delayed extraction
- Main page
- deprotonated molecule
- desorption ionization
- diagnostic ion
- dimeric ion
- direct exposure probe
- direct insertion probe
- direct liquid introduction
- dissociative ionization
- distonic ion
- Main page
- double-focusing mass spectrometer
- dynamic field mass spectrometer
E
- einzel lens
- Main page
- electric sector
- Redirects to sector instrument
- electron affinity
- Main page
- electron attachment ionization
- Redirects to Electron capture ionization
- electron capture ionization
- Main page
- electron capture dissociation
- Main page
- electron energy
- electron impact ionization
- Redirects to Electron ionization
- electron ionization
- Main page
- electronvolt
- Main
- electrospray ionization
- Main page
- electrostatic energy analyzer
- Redirects to Electrostatic analyzer
- even-electron ion
- even-electron rule
- exact mass
- Section of Mass (mass spectrometry)
F
- Faraday cup
- Main page
- Fast atom bombardment
- Main page
- field desorption
- Main page
- field desorption/ionization
- Redirects to Field desorption
- field-free region
- field ionization
- Redirects to Field desorption
- first stability region
- fission fragment ionization
- Redirects to Plasma desorption mass spectrometry
- focal plane detector
- forward library search
- Fourier transform ion cyclotron resonance mass spectrometer
- Main page
- fragment ion
- fringe field
G
- glow discharge ionization
- Redirects to Electric glow discharge
H
- hard ionization
- high-energy collision-induced dissociation
- redirects to collision-induced dissociation
- high-field asymmetric waveform ion mobility spectrometry
- Main page
- hydrogen/deuterium exchange
- Main page
- hybrid mass spectrometer
- Main page
I
- imaging mass spectrometry
- inductively coupled plasma
- infrared multiphoton dissociation
- in-source collision-induced dissociation
- ion
- ion cyclotron resonance mass spectrometer
- ion desolvation
- ion energy loss spectrum
- ion gate
- ionic dissociation
- ion reaction
- ionization efficiency
- ionizing collision
- ion kinetic energy spectrometry
- ion mobility spectrometry
- ion/molecule reaction
- ion/neutral complex
- ion/neutral reaction
- ion/neutral exchange reaction
- ion pair formation
- ion source
- ionspray
- ion-to-photon detector
- ion trap
- isotope dilution mass spectrometry
- isotope ratio mass spectrometry
- isotopolog ions
- isotopomeric ions
K
L
- laser desorption
- laser desorption/ionization
- wikipedia:laser ionization
- laser microprobe mass spectrometry
- Redirects to microbrobe
- linear ion trap
- Redirects to ion trap
- linked scan
- liquid secondary ionization
- Redirects to Secondary ionization
- low-energy collision-induced dissociation
- Redirects to collision-induced dissociation
M
- magnetic sector
- Redirects to Sector instrument
- mass-analyzed ion kinetic energy spectrometry
- Main page
- mass calibration
- mass defect
- mass excess
- Main page
- mass gate
- mass limit
- mass number
- Main page
- mass range
- mass resolution
- Redirects to Resolution (mass spectrometry)
- mass resolving power
- Redirects to Resolution (mass spectrometry)
- mass selective axial ejection
- mass selective instability
- mass spectral library
- mass spectrograph
- mass spectrometer
- mass spectrometry|mass spectrometry/mass spectrometry
- tandem mass spectrometry
- Main page
- mass spectrum
- mass-to-charge-ratio
- Mathieu stability diagram
- matrix-assisted laser desorption/ionization
- Mattauch-Herzog geometry
- McLafferty rearrangement
- membrane introduction mass spectrometry
- metastable ion
- microchannel plate
- molar mass
- molecular beam mass spectrometry
- molecular ion
- wikipedia:molecular weightmolecular weight
- monoisotopic mass
- MS/MS spectrum
- MSn
- multiphoton ionization
- multiple reaction monitoring
- multiple-stage mass spectrometry
- m/z
N
- nanoelectrospray
- nanospray
- negative ion
- negative ion chemical ionization
- neutralization reionization mass spectrometry
- neutral loss
- Nier-Johnson geometry
- nitrogen rule
- nominal mass
- non-classical ion
- nth generation product ion
- nth generation product ion spectrum
O
P
- Parent ion
- Parent ion spectrum
- Paul ion trap
- peak (in mass spectrometry)
- peak intensity
- peak matching
- Penning ionization
- Penning ion trap
- photodissociation
- photoionization
- photon impact
- plasma desorption/ionization
- pneumatically-assisted electrospray ionization
- point detector
- positive ion
- post-acceleration detector
- post-source decay
- precursor ion
- precursor ion spectrum
- pre-ionization state
- principal ion
- product ion
- product ion analysis
- product ion spectrum
- proton affinity
- protonated molecular ion
- protonated molecule
- pseudo-molecular ion
- pyrolysis mass spectrometry
Q
R
- radical ion
- reagent gas
- reagent ion
- recombination energy
- reference ion
- reflectron
- Main page
- residual gas analyzer
- Main page
- resonance-enhanced multiphoton ionization
- resonance ion ejection
- resonance ionization
- reverse library search
- RF-DC ion mobility spectrometry
- RF-only quadrupole
S
- secondary electron
- secondary ionization
- Main page
- secondary neutral mass spectrometry
- sector mass spectrometer
- Redirects to Sector instrument
- selected ion flow tube
- selected ion monitoring
- Redirects to Mass chromatogram
- selected ion recording
- selected reaction monitoring
- Redirects to Mass chromatogram
- self-chemical ionization
- soft ionization
- sonic spray ionization
- Main page
- space charge effect
- Redirects to Space charge
- spark ionization
- Main page
- stable ion
- stability diagram
- static field
- stored waveform inverse Fourier transform
- surface-induced dissociation
- surface-induced reaction
- surface ionization
- sustained off-resonance irradiation
T
- tandem mass spectrometer
- tandem mass spectrometry
- Main page
- tandem mass spectrometry in time
- tandem mass spectrometry in space
- target gas
- thermal ionization
- Main page
- thomson
- Disambiguates to Thomson (unit)
- time-of-flight mass spectrometer
- Redirects to Time-of-flight mass spectrometry
- time-of-flight mass spectrometry
- Main page
- time-lag focusing
- Redirects to Delayed extraction
- total ion current
- total ion current chromatogram
- Redirects to Mass chromatogram
- transmission efficiency
- transmission quadrupole mass spectrometer
- Redirects to Quadrupole mass analyzer
- triple quadrupole mass spectrometer
- Main page
U
V
- vertical ionization
- Redirects to Gas phase ion chemistry
X
- x-ion
- Redirects to Peptide sequence tag
Y
- y-ion
- Redirects to Peptide sequence tag
Z
- z-ion
- Redirects to Peptide sequence tag
