Abundance sensitivity

From Mass Spectrometry Terms
Jump to: navigation, search
IUPAC RECOMMENDATIONS 2013

K. K. Murray, R. K. Boyd, M. N. Eberlin, G. J. Langley, L. Li and Y. Naito, Pure Appl. Chem., 2013, 85, 1515-1609, 10.1351/PAC-REC-06-04-06.

Abundance sensitivity
Ratio of the maximum ion current recorded at a specified m/z value to the maximum ion current arising from the same species recorded at a neighbouring m/z value.

Note: The abundance sensitivity is a measure of the contribution of the peak “tail” of a major isotope (with a certain m/z value) to an adjacent m/z value which in some cases might more than 1 m/z removed. Its value is dependent on the resolving power of the mass spectrometer.

Related Term(s):
Reference(s):

IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the “Orange Book”). Definitive Rules, 1979. Compiled by J. Inczédy, T. Lengyel, A. M. Ure. Blackwell Scientific Publications, Oxford (1997). On-line corrected version: http://www.iupac.org /publications/analytical compendium (2000).

IUPAC. Compendium of Chemical Terminology, 2nd ed. (the “Gold Book”). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). XML on-line corrected version: http://goldbook.iupac.org (2006-) created by M. Nic, J. Jirat, B. Kosata; updates compiled by A. Jenkins.

Y. H. Kim, S. Kim. J. Am. Soc. Mass Spectrom. 21, 386–392 (2010).

Definitions of Terms Relating to Mass Spectrometry (IUPAC Recommendations 2013); DOI: 10.1351/PAC-REC-06-04-06 © IUPAC 2013.


Index of Terms

 




Orange Book

ORANGE BOOK DEFINITION

IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the “Orange Book”). Definitive Rules, 1979.

Abundance sensitivity

The ratio of the maximum ion current recorded at a mass m to the ion current arising from the same species recorded at an adjacent mass (m + 1).

IUPAC Orange Book Chapter 12
Index of Orange Book Terms


Gold Book

GOLD BOOK DEFINITION

IUPAC. Compendium of Chemical Terminology, 2nd ed. (the “Gold Book”). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997).

Abundance sensitivity

http://goldbook.iupac.org/A00048.html

The ratio of the maximum ion current recorded at a mass to the ion current arising from the same species recorded at an adjacent mass (). Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1554

IUPAC Gold Book