Dynamic field mass spectrometer: Difference between revisions

From MS Terms
No edit summary
No edit summary
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Def2|
{{Final
A [[mass spectrometer]] in which ''[[m/z]]'' separation using one or more electric fields that vary with time.
|acronym=
|def=[[Mass spectrometer]] in which ''[[m/z]]'' separation is achieved using one or more electric fields that vary with time.
|rel=
|ref= {{obgb}}
}}
}}


== [[Orange Book]] Entry ==
<!-- Orange Book -->
{{orange|
{{orange|
A [[mass spectrometer]] in which the separation of a selected ion beam depends essentially on the use of fields, or a field, (generally electric) varying with time.
A [[mass spectrometer]] in which the separation of a selected ion beam depends essentially on the use of fields, or a field, (generally electric) varying with time.
}}
}}
[[Category:m/z Separation]]
 
<!-- Gold Book -->
{{gold|
http://goldbook.iupac.org/D01871.html
 
A mass spectrometer in which the separation of a selected ion beam depends essentially on the use of fields, or a field, varying with time. These fields are generally electric.
 
'''Source''':
 
PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1545
 
[[Orange Book]], p. 202
}}
 
[[Category:M/z Separation]]
{{DEFAULTSORT:Dynamic Field Mass Spectrometer}}
[[Category:Orange Book term]]

Latest revision as of 12:38, 3 January 2014

IUPAC RECOMMENDATIONS 2013
Dynamic field mass spectrometer
Mass spectrometer in which m/z separation is achieved using one or more electric fields that vary with time.
Related Term(s):
Reference(s):

IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979. Compiled by J. Inczédy, T. Lengyel, A. M. Ure. Blackwell Scientific Publications, Oxford (1997). On-line corrected version: http://www.iupac.org /publications/analytical compendium (2000).

IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). XML on-line corrected version: http://goldbook.iupac.org (2006-) created by M. Nic, J. Jirat, B. Kosata; updates compiled by A. Jenkins.

From Definitions of Terms Relating to Mass Spectrometry (IUPAC Recommendations 2013); DOI: 10.1351/PAC-REC-06-04-06 © IUPAC 2013.

Index of Recommended Terms

 




Orange Book

ORANGE BOOK DEFINITION

IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023)

Dynamic field mass spectrometer

A mass spectrometer in which the separation of a selected ion beam depends essentially on the use of fields, or a field, (generally electric) varying with time.

IUPAC 1997 Orange Book Chapter 12
Index of Orange Book Terms


Gold Book

GOLD BOOK DEFINITION

IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997).

Dynamic field mass spectrometer

http://goldbook.iupac.org/D01871.html

A mass spectrometer in which the separation of a selected ion beam depends essentially on the use of fields, or a field, varying with time. These fields are generally electric.

Source:

PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1545

Orange Book, p. 202

IUPAC Gold Book
Index of Gold Book Terms