Fourier transform-ion cyclotron resonance-mass spectrometer: Difference between revisions
No edit summary |
|||
Line 4: | Line 4: | ||
== [[Orange Book]] Entry == | == [[Orange Book]] Entry == | ||
{{orange| | |||
A high-frequency [[mass spectrometer]] in which the [[Cyclotron Motion|cyclotron motion]] of ions, having different [[mass/charge ratio]]s, in a constant magnetic field, is excited essentially simultaneously and coherently by a pulse of a radio-frequency electric field applied perpendicularly to the magnetic field. The excited cyclotron motion of the ions is subsequently detected on [[Receiver Plate|receiver plate]]s as a time domain signal that contains all the [[Cyclotron Frequency|cyclotron frequencies]] excited. Fourier transformation of the time domain signal results in a frequency domain FT-ICR signal which, on the basis of the inverse proportionality between frequency and mass/charge ratio, can be converted to a [[mass spectrum]]. See also [[ICR|ion cyclotron resonance (ICR) mass spectrometer]]. | A high-frequency [[mass spectrometer]] in which the [[Cyclotron Motion|cyclotron motion]] of ions, having different [[mass/charge ratio]]s, in a constant magnetic field, is excited essentially simultaneously and coherently by a pulse of a radio-frequency electric field applied perpendicularly to the magnetic field. The excited cyclotron motion of the ions is subsequently detected on [[Receiver Plate|receiver plate]]s as a time domain signal that contains all the [[Cyclotron Frequency|cyclotron frequencies]] excited. Fourier transformation of the time domain signal results in a frequency domain FT-ICR signal which, on the basis of the inverse proportionality between frequency and mass/charge ratio, can be converted to a [[mass spectrum]]. See also [[ICR|ion cyclotron resonance (ICR) mass spectrometer]]. | ||
}} | |||
== External Links == | == External Links == |
Revision as of 21:12, 9 July 2009
Obsolete Template
Orange Book Entry
Orange Book
ORANGE BOOK DEFINITION
IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) |
Fourier transform-ion cyclotron resonance-mass spectrometer |
---|
A high-frequency mass spectrometer in which the cyclotron motion of ions, having different mass/charge ratios, in a constant magnetic field, is excited essentially simultaneously and coherently by a pulse of a radio-frequency electric field applied perpendicularly to the magnetic field. The excited cyclotron motion of the ions is subsequently detected on receiver plates as a time domain signal that contains all the cyclotron frequencies excited. Fourier transformation of the time domain signal results in a frequency domain FT-ICR signal which, on the basis of the inverse proportionality between frequency and mass/charge ratio, can be converted to a mass spectrum. See also ion cyclotron resonance (ICR) mass spectrometer. |
IUPAC 1997 Orange Book Chapter 12 |