{{ | {{Final | ||
|acronym= | |||
|def=Device for spatially confining [[ion]]s using electric and magnetic fields alone or in combination. | |||
|rel= | |||
|ref={{obgb}} | |||
A. G. Marshall, C. L. Hendrickson, G. S. Jackson. Mass Spectrom. Rev. 17, 1 (1998). ([http://goo.gl/4kP05 http://dx.doi.org/10.1002/(SICI)1098-2787(1998)17:1<1::AID-MAS1>3.0.CO;2-K]) | |||
J. P. Holder, L. Gruber, H. E. DeWitt, B. R. Beck, D. A. Church, D. Schneider. Phys. Scr., T 92, 158 (2001). | |||
{{psims}}1000264 | |||
}} | |||
<!-- Orange Book --> | |||
{{orange| | |||
A device that permits the ejection of ions with a [[m/z ratio]] less than a prescribed value and retention of those with higher mass. It depends on the application of radio frequency voltages between a ring electrode and two end-cap electrodes to confine the ions in a circular path. The choice of these voltages determines the [[m/z ratio]] below which ions are ejected. Unlike the [[Ion Cyclotron Resonance Spectrometer]] no magnetic field is required for the operation of the ion trap. | A device that permits the ejection of ions with a [[m/z ratio]] less than a prescribed value and retention of those with higher mass. It depends on the application of radio frequency voltages between a ring electrode and two end-cap electrodes to confine the ions in a circular path. The choice of these voltages determines the [[m/z ratio]] below which ions are ejected. Unlike the [[Ion Cyclotron Resonance Spectrometer]] no magnetic field is required for the operation of the ion trap. | ||
}} | |||
{{psi| | |||
|def=A device for spatially confining ions using electric and magnetic fields alone or in combination. | |||
|sup=mass analyzer type | |||
|id=1000264 | |||
|syn=IT | |||
|anno= | |||
}} | |||
[[Category:M/z Separation]] | |||
[[ | |||
Revision as of 21:40, 9 May 2016
IUPAC RECOMMENDATIONS 2013 |
Ion trap |
---|
Device for spatially confining ions using electric and magnetic fields alone or in combination. |
Related Term(s): |
Reference(s):
IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979. Compiled by J. Inczédy, T. Lengyel, A. M. Ure. Blackwell Scientific Publications, Oxford (1997). On-line corrected version: http://www.iupac.org /publications/analytical compendium (2000). IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). XML on-line corrected version: http://goldbook.iupac.org (2006-) created by M. Nic, J. Jirat, B. Kosata; updates compiled by A. Jenkins. A. G. Marshall, C. L. Hendrickson, G. S. Jackson. Mass Spectrom. Rev. 17, 1 (1998). (http://dx.doi.org/10.1002/(SICI)1098-2787(1998)17:1<1::AID-MAS1>3.0.CO;2-K) J. P. Holder, L. Gruber, H. E. DeWitt, B. R. Beck, D. A. Church, D. Schneider. Phys. Scr., T 92, 158 (2001).
|
From Definitions of Terms Relating to Mass Spectrometry (IUPAC Recommendations 2013); DOI: 10.1351/PAC-REC-06-04-06 © IUPAC 2013. |
Orange Book
ORANGE BOOK DEFINITION
IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979 (see also Orange Book 2023) |
Ion trap |
---|
A device that permits the ejection of ions with a m/z ratio less than a prescribed value and retention of those with higher mass. It depends on the application of radio frequency voltages between a ring electrode and two end-cap electrodes to confine the ions in a circular path. The choice of these voltages determines the m/z ratio below which ions are ejected. Unlike the Ion Cyclotron Resonance Spectrometer no magnetic field is required for the operation of the ion trap. |
IUPAC 1997 Orange Book Chapter 12 |
Index of Orange Book Terms |
Proteomics Standards Initiative Term |
Ion trap |
---|
A device for spatially confining ions using electric and magnetic fields alone or in combination. |
Superclasses: mass analyzer type |
ID: MS:1000264
Synonym: IT
|