Difference between revisions of "Mattauch-Herzog geometry"
(rm section heads , Replaced: == Orange Book entry == ‚Üí <!-- Orange Book -->, using AWB) |
|||
Line 1: | Line 1: | ||
{{Def2| | {{Def2| | ||
An arrangement for a [[double-focusing mass spectrometer]] in which a deflection of π/(4 √(2)) radians in a radial [[electric field]] is followed by a [[magnetic deflection]] ofπ/2 radians. | An arrangement for a [[double-focusing mass spectrometer]] in which a deflection of π/(4 √(2)) radians in a radial [[electric field]] is followed by a [[magnetic deflection]] ofπ/2 radians. | ||
+ | }} | ||
+ | |||
+ | {{rev5 | ||
+ | | | ||
+ | An arrangement for a double-focusing mass spectrograph in which a deflection of ?/(4 ?(2)) radians in a radial electrostatic energy analyzer is followed by a magnetic deflection of ?/2 radians. | ||
+ | |||
+ | Related term: [[Nier-Johnson geometry]]. | ||
+ | | | ||
+ | #[[Gold Book]] | ||
+ | #[[Orange Book]] | ||
}} | }} | ||
Line 8: | Line 18: | ||
}} | }} | ||
+ | {{gold| | ||
+ | http://goldbook.iupac.org/M03761.html | ||
+ | |||
+ | An arrangement for a double-focusing mass spectrograph in which a deflection of radians in a radial electrostatic field is followed by a magnetic deflection of radians. | ||
+ | |||
+ | Source: | ||
+ | PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1546 | ||
+ | }} | ||
== See also == | == See also == | ||
*[[Double-focusing Mass Spectrometer]] | *[[Double-focusing Mass Spectrometer]] |
Revision as of 03:27, 6 June 2010
Obsolete Template
This template is no longer used.
Orange Book
ORANGE BOOK DEFINITION
IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979. |
Mattauch-Herzog geometry |
---|
An arrangement for a double-focusing mass spectrograph in which a deflection of π/(4 √(2)) radians in a radial electrostatic field is followed by a magnetic deflection of π/2 radians. |
IUPAC 1997 Orange Book Chapter 12 |
Index of Orange Book Terms |
Gold Book
GOLD BOOK DEFINITION
IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). |
Mattauch-Herzog geometry |
---|
http://goldbook.iupac.org/M03761.html An arrangement for a double-focusing mass spectrograph in which a deflection of radians in a radial electrostatic field is followed by a magnetic deflection of radians. Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1546 |
IUPAC Gold Book |
Index of Gold Book Terms |