Peak parking

From MS Terms Wiki
Revision as of 03:36, 7 January 2014 by Kkmurray (talk | contribs) (Created page with '{{Final |acronym= |def=Data analysis technique used in elemental mass spectrometry to correct the intensity of an unresolved multiplet peak monitored for a specific element f…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
IUPAC RECOMMENDATIONS 2013
Peak parking
Data analysis technique used in elemental mass spectrometry to correct the intensity of an unresolved multiplet peak monitored for a specific element for contributions from a multi-isotopic contaminant. The correction is calculated from the measured intensity of a different isotopic peak of the contaminant and the known natural isotopic abundance ratio.
Related Term(s):
Reference(s):

F. Li, J. Maguigad, M. Pelzer, X. Jiang, Q. C. Ji. Rapid Commun. Mass Spectrom. 22, 486 (2008). (http://dx.doi.org/10.1002/rcm.3389 )

From Definitions of Terms Relating to Mass Spectrometry (IUPAC Recommendations 2013); DOI: 10.1351/PAC-REC-06-04-06 © IUPAC 2013.