Difference between revisions of "Selected ion monitoring"
Line 15: | Line 15: | ||
Source: PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1551 | Source: PAC, 1991, 63, 1541 ([[Recommendations for nomenclature and symbolism for mass spectroscopy]] (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1551 | ||
+ | }} | ||
+ | |||
+ | {{jchrom| | ||
+ | The operation of a [[mass spectrometer]] in which the abundance of one or more ions is measured as a function of time rather than the entire [[mass spectrum]]. | ||
+ | | | ||
+ | #J.F.J. Todd, Int. J. Mass Spectrom. Ion Processes 142 (1995) 211. | ||
}} | }} | ||
Revision as of 00:39, 5 April 2010
Obsolete Template
Orange Book
ORANGE BOOK DEFINITION
IUPAC. Analytical Division. Compendium of Analytical Nomenclature (the Orange Book). Definitive Rules, 1979. |
Selected ion monitoring |
---|
This term is used to describe the operation of the mass spectrometer in which the intensities of several specific ion beams are recorded rather than the entire mass spectrum. An alternative recommended term is multiple ion (peak) monitoring. The use of the terms multiple ion detection and 'mass fragmentography' is not recommended. |
IUPAC 1997 Orange Book Chapter 12 |
Index of Orange Book Terms |
Gold Book
GOLD BOOK DEFINITION
IUPAC. Compendium of Chemical Terminology, 2nd ed. (the Gold Book). Compiled by A. D. McNaught and A.Wilkinson. Blackwell Scientific Publications, Oxford (1997). |
Selected ion monitoring |
---|
http://goldbook.iupac.org/S05547.html This term is used to describe the operation of the mass spectrometer in which the intensities of several specific ion beams are recorded rather than the entire mass spectrum. An alternative recommended term is multiple ion (peak) monitoring. The use of the terms multiple ion detection and mass fragmentography are not recommended, because in the case of the former, it is the monitoring of several peaks which should be emphasized rather than the detection of different ions, and in the case of the latter it is often not fragments that are being monitored but peaks from molecular ions. Source: PAC, 1991, 63, 1541 (Recommendations for nomenclature and symbolism for mass spectroscopy (including an appendix of terms used in vacuum technology). (Recommendations 1991)) on page 1551 |
IUPAC Gold Book |
Index of Gold Book Terms |