Selected reaction monitoring: Difference between revisions
From MS Terms
No edit summary |
No edit summary |
||
(7 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{ | {{Final|acronym=SRM | ||
Data acquired from specific [[ | |def=Data acquired from one or more specific product [[ion]]s corresponding to [[m/z]] selected [[precursor ion]]s recorded via two or more stages of [[mass spectrometry]]. | ||
:''Note 1'': Selected reaction monitoring in [[multiple-stage mass spectrometry]] is known as [[consecutive reaction monitoring]]. | |||
:''Note 2'': Selected reaction monitoring applied to multiple product ions from one or more [[precursor ion]]s is known as multiple reaction monitoring. | |||
|rel=[[selected ion monitoring]] | |||
|ref=E. de Hoffmann. J. Mass Spectrom. 31, 129 (1996). | |||
}} | }} | ||
{{rm}} | |||
[[Category:Reactions]] | [[Category:Reactions]] | ||
{{DEFAULTSORT:Selected Reaction Monitoring}} | {{DEFAULTSORT:Selected Reaction Monitoring}} | ||
[[Category:Reaction monitoring]] |
Latest revision as of 13:02, 31 August 2017
IUPAC RECOMMENDATIONS 2013 |
Selected reaction monitoring SRM |
---|
Data acquired from one or more specific product ions corresponding to m/z selected precursor ions recorded via two or more stages of mass spectrometry.
|
Related Term(s): selected ion monitoring |
Reference(s):
E. de Hoffmann. J. Mass Spectrom. 31, 129 (1996). |
From Definitions of Terms Relating to Mass Spectrometry (IUPAC Recommendations 2013); DOI: 10.1351/PAC-REC-06-04-06 © IUPAC 2013. |
IUPAC reaction monitoring terms
Term Acronym Definition Diagram Reference Selected ion monitoring SIM Operation of a mass spectrometer in which the abundances of ions of one or more specific m/z values are recorded rather than the entire mass spectrum. . Gold Book Selected reaction monitoring SRM Data acquired from one or more specific product ions corresponding to m/z selected precursor ions recorded via two or more stages of mass spectrometry. - Note 1: Selected reaction monitoring in multiple-stage mass spectrometry is known as consecutive reaction monitoring.
- Note 2: Selected reaction monitoring applied to multiple product ions from one or more precursor ions is known as multiple reaction monitoring.
de Hoffmann. J. Mass Spectrom. 31, 129 (1996). Consecutive reaction monitoring CRM Multiple-stage mass spectrometry experiment with three or more stages of m/z separation in which products of sequential fragmentation or bimolecular reactions are selected for detection. Tomer, Guenat, Deterding. Anal. Chem. 60, 2232 (1988). Multiple reaction monitoring MRM Application of selected reaction monitoring to multiple product ions from one or more precursor ions. - Note: This term should not be confused with consecutive reaction monitoring, which involves the serial application of three or more stages of selected reaction monitoring.
Roepstorff, Fohlman. Biomed. Mass Spectrom. 11, 601 (1984).